• Other Fluke companies:
  • Fluke
  • Fluke Biomedical
  • Fluke Networks
  • Fluke Process Instruments
See more Fluke brands
Accelix Amprobe Beha-Amprobe Comark Emaint Landauer Pacific Laser Systems Pomona RaySafe Schad
Home
Precision, Performance, Confidence.
Fluke Calibration: US
  • Register
  • Log in
  • Contact Us

US - English [Change]

 

Get Quote

RF Calibration

The 96040A 4GHZ and 96270A 27GHz RF reference sources are the core of an RF calibration system, maximizing utility and efficiency. Designed specifically for RF Calibration these products provide superior phase noise performance, an integrated frequency counter, and wide-offset phase noise filter accessory.

Request a Quote
Keep me informed
RF Reference Sources
RF Reference Sources »
RF Calibration Accessories
RF Calibration Accessories »
RF Calibration Software
RF Calibration Software »

Learn about RF calibration and how to choose a calibrator

What frequency ranges are covered by RF and microwave calibration?

Radio frequency and microwave (RF and microwave) calibration take over at the higher frequencies beyond those encountered in dc and low frequency ac (dc lf) calibration. The boundary is somewhat blurred, but most metrologists consider it to be in the 1 – 10 MHz region. RF and microwave calibration activities are often undertaken in separate labs within a calibration facility, with microwave calibration taking place in yet another area. Again there is no specific boundary, but microwave frequencies are generally considered to be those above a few GHz. At even higher frequencies, around 100 GHz, the term millimeter wave is often used. Regardless of a calibration facility’s approach to frequency segregation, there are many common elements.

How do RF and microwave and dc/lf calibration differ?

The most significant is that RF and microwave equipment and systems employ matched transmission lines for interconnection (coaxial cables or waveguides at higher frequencies).

What parameters are measured in RF calibration?

Two key parameters are RF power and a measure of how well it is matched or delivered from a source to a load. The quality of match to the transmission line characteristic impedance is typically expressed in terms such as voltage standing wave ratio (VSWR), reflection coefficient and S-parameters, etc.

Mismatch errors are major contributions to measurement uncertainty in RF calibration. These arise from the output and input matches of the equipment and from the cables and connectors used to interconnect the equipment. Using high quality metrology grade connectors and cables, and treating them with care are essential in minimizing these sources of error and uncertainty.

Many other parameters and characteristics are measured when calibrating RF and microwave test equipment, too numerous (and often instrument-specific) to discuss here.

How is RF calibration traditionally performed?

Unlike dc /lf calibration where there are many dedicated calibrators, in RF and microwave there are virtually no specifically designed calibrators (apart from the Fluke Calibration 96000 Series RF Reference Sources). To calibrate an RF and microwave workload item, it is necessary to collect a variety of different pieces of test equipment to provide the required functionality and performance.

The equipment may be assembled as a system dedicated to a particular type of instrument, as a system capable of calibrating many workload instrument types, or simply collected from the lab inventory for a specific calibration task and dispersed when the task is completed.

Because so many system instruments are involved, there are many different setups required to make connections to the unit or device under test (UUT/DUT). Switching and multiplexing is not possible due to the measurement errors and uncertainty contributions that would be introduced by the switching, particularly at the higher frequencies.

The calibration process may be performed manually, or it may be automated using software to take control of the system instruments and the item being calibrated. Fully automated RF and microwave calibrations are rare due to the difficulty in automating signal switching without degrading measurement quality.

Traditional automated systems need frequent user intervention to change the interconnections. Consequently there are many opportunities for mistakes and highly trained staff is needed. Costly operator time is often wasted waiting for the next setup change.

What instrument types are typically found in an RF and microwave calibration system?

Instruments usually found in a traditional system include: signal generators, level generator, function generator, power meters, measuring receiver, spectrum analyzer, RF and microwave counters, network analyzer, audio analyzer, oscilloscope, digital multimeter. None of these instruments are designed specifically for calibration; they are all general purpose test instruments that get used in the system. The signal generators are not capable of the performance needed in RF calibration. So they must be used with power meters and calibrated step attenuators to provide sufficient level and attenuation accuracy. External filters are required when low harmonic is important, such as in spectrum analyzer calibration. Signal sources with low phase noise performance are also required for high-performance spectrum analyzer calibration.

What is the RF and microwave calibration workload?

Often the same instruments used within the systems appear as calibration workload. Signal generators, spectrum analyzers, power meters, power sensors are the most common workload items. Others include RF millivoltmeters, signal level meters, modulation analyzers receivers and counter/timers.

What is the opportunity to improve efficiency and reduce costs?

Employing a Fluke Calibration 96000 Series RF Reference Source, specifically designed for RF calibration, as the core of an RF and microwave calibration system enables many system instruments and accessories to be replaced by just one. The unique combination of features and performance makes the 96000 Series clearly superior to general purpose signal generators. Used manually or partnered with MET/CAL Calibration Software, a 96000 Series Reference Source can halve system costs, improve system capacity by up to 25% and free up 50% of the system operator's time to perform other value-adding tasks.

The 27 GHz 96270A Reference Source covers more than 80% of the test points required for calibrating almost all spectrum analyzers of any frequency range. For many spectrum analyzers operating below 27 GHz, you can perform the entire calibration with a 96270A, or with a 96040A Reference Source for lower frequency models operating below 4 GHz.

The integrated dual power meter readout capabiities of the 96270A also allow you to make RF level measurements to calibrate signal generators, spectrum analyzer tracking generator outputs, and other signal source workload where a separate power meter would usually be required.

The 96000 Series integrated frequency counter lets you reduce the number of instruments required for RF calibration even further.

Further information

A guide to calibrating your spectrum analyzer »
RF calibration best practice guide: coaxial connectors »
Understanding phase noise in RF and microwave calibration applications »
Measuring and Certifying Phase Noise Performance of a Low-Noise RF »

What are the traditional RF calibration solutions?

There are virtually no instruments specifically designed as RF and microwave calibrators (apart from the Fluke Calibration 96000 Series). RF and microwave calibration procedures are complex, involving many general purpose test instruments, accessories, components, cables, adapters and connectors. Calibration solutions are generally created by users developing and assembling their own systems. Automation is often provided by users writing their own software or employing commercially available test system automation software. Larger organizations may commission systems integrators to put together a calibration system. Some test equipment manufacturers offer software packages for calibrating their own RF and microwave products, which only allows use of their own products as calibration standards and cannot calibrate any other workload.

What RF calibration solution does Fluke Calibration offer?

Employing a Fluke Calibration 96000 Series Reference Source, specifically designed for RF calibration, as the core of an RF and microwave calibration system enables many system instruments and accessories to be replaced by just one. The unique combination of features and performance makes the 96000 Series clearly superior to general purpose signal generators. used manually or partnered with MET/CAL Calibration Software, a 96000 Series Reference source can halve system costs, imprpove system capacity by up to 25% and free up 50% of the system operator's time to perform other value-adding tasks

The 27 GHz 96270A Reference Source covers more than 80% of the test points required for calibrating almost all spectrum analyzers of any frequency range. For many spectrum analyzers operating below 27 GHz, you can perform the entire calibratoin with a 96270A.

What factors should be considered when selecting a solution?

Efficiency

In a typical automated RF calibration process, the operator must intervene frequently to change test setups, thus limiting the benefits that can be realized by the automation. Walk-away automation can increase calibration system capacity by 25 percent or more using procedures developed in MET/CAL Calibration Software. Fluke Calibratoin includes a sample calibration procedure with the 96270A and 96040A, which you can use as the basis for creating additional RF calibration procedures to handle your unique workload.

MET/CAL procedures created by Fluke Calibration for the 9620A models can also be used by the 96270A and the 96040A in 9640A emulation mode.

The 96270A and 96040A are also integrated easily into existing automated systems and software. The time savings and efficiency gains offered by these models can be realized by structuring test sequences to take full advantage of its "connect once measure many" capabilities.

Workload coverage and degree of automation

Workload coverage refers to instrument type and its manufacturer; degree of automation means the extent to which a solution addresses its calibration and provides automation.

Spectrum analyzers are key workload items for any RF and microwave calibration lab. The 96000 Series Reference Sources provide the required functionality and performance, and with their superior low phase noise performance, the 96270A and 96040A are capable of calibrating the high-end spectrum analyzers.

The 96000 Series features and performance also make them ideal for other workload, including RF millivoltmeters, signal level meters, modulation analyzers, receivers and counter/timers..

The 9640A Series features and performance also make it ideal for other workload, including RF millivoltmeters, signal level meters, modulation analyzers, receivers and counter/timers.

Some RF calibration software packages are only capable of calibrating single-vendor UUTs and also require single vendor system instruments. MET/CAL calibration software does not have this limitation.

Operator skill levels and opportunity for errors

RF and microwave calibration is complex, and finding skilled staff can be challenging. The staff possessing the required knowledge and skill have many tasks to perform, and freeing their time to tackle the tasks where utilizing those skill adds the most value is an important consideration in choosing a calibration solution.

Compatibility with existing standards, automation and processes

Use MET/CAL software’s Flexible Standards feature to automate the other instruments in your system. This capability allows you to substitute equivalent standards within the procedures, so you aren’t locked into a specific reference model. Flexible Standards support is available for popular microwave synthesizers including the HP8340, HP83630, Agilent E8254 and E8257, and other models from Anritsu and Rohde & Schwarz.

The 96000 Series Reference Sources are designed to match or exceed the performance and functionality of the HP3335A and HP8662/3A in the calibration system. Replacing these popular but obsolete and difficult to maintain products becomes just a plug-and-play substitution. HP8662/3A GPIB command emulation is installed as standard on the 96270A and 96040A. The 96270A also includes as standard GPIB command emulation for th eHP8340A, HP38630B Series and the Agilent E8257 Series models.

Simplicity and indirect costs

Systems with many instruments are complex and expensive to support and maintain. The reduction in system instrument count achieved with a 96000 Series Reference Source brings many benefits. Metrology is significantly simpler, with fewer error sources and fewer uncertainty contributions. System support costs are reduced, as there are fewer instruments to calibrate and maintain.

On-site portability

A smaller, compact system is ideal for on-site use, reducing transport costs and also enabling a system to be easily taken to locations inappropriate for a larger system.

What other RF applications might benefit from a signal source with precision and performance improvements?

Many applications in R&D, manufacturing test, ATE, and scientific research require better performance than a general purpose signal generator. The 96000 Series' unique combination of level and attenuation accuracy, signal purity and low jitter, frequency resolution, dynamic range and precision modulation deliver better performance than any high performance signal generator in these applications.

Request a Quote
Keep me informed
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
    • Handheld Test Tools
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • "How To" Seminars
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Resource Centers
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Safety Data Sheets (SDS)
    • Safety, Service, and Product Notices
    • Software Downloads
    • Tools
      • PT100 Calculator
      • PT100 Table Generator
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
    • Why buy Fluke Calibration ?
Home|Products|RF Calibration

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

Products

  • Product index
  • New products
  • Where to buy
  • Request a quote

Services

  • Calibration and repair
  • About Fluke Calibration
  • Service centers
  • Software downloads

Resources

  • Catalogs
  • Manuals
  • Web seminars
  • Subscribe to e-news
  • Supplier Handbook

Company

  • Contact us
  • About Fluke Calibration
  • Why choose us
  • Other Fluke companies
©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Terms of Use
  • Terms of Sale