- Other Fluke companies:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
Electrical Calibration Workload Matrix
Use this guide to help choose the right electrical calibrator for your application.
This guide summarizes the functions, accuracies and targeted workload of every Fluke Calibration electrical calibrator; including electrical multi-product calibrators, multifunction calibrators, oscilloscope calibrators, electrical tester calibrators, power and energy calibrators and standards, and precision process calibrators. This selection guide is intended to help you decide which calibrator best fits which class of test equipment and the associated performance levels required.
For additional help selecting an electrical calibrator, speak with one of our equipment specialists.
Multi-Product Calibrators | Multifunction Calibrators | Oscilloscope Calibrators | Electrical Tester Calibrator | Power and Energy Calibrators | Temperature and Pressure Calibrator | |||||
---|---|---|---|---|---|---|---|---|---|---|
Workload | 5080A | 5540A | 5550A | 5560A | 5730A | 9500B | 5322A | 6100B | 6105A | 7526A |
Analog/panel meters | ||||||||||
High burden meters | ||||||||||
Low burden meters | V DC and V AC | V DC, I DC and R | ||||||||
DMMs | ||||||||||
Basic DC V accuracy at 99 % | 100 ppm | 31 ppm | 11 ppm | 8 ppm | 4.5 ppm | n/a | 1000 ppm | 112 ppm | 42 ppm | 40 ppm |
3.5 digits (typ. ± 0.3 % DC V) |
V DC and V AC | V DC and V AC | ||||||||
4.5 digits (typ. ± 0.025 % DC V) |
||||||||||
5.5 digits (typ. ± 0.015 % DC V) |
||||||||||
6.5 digits (typ. ± 0.0030 % DC V) |
||||||||||
7.5 digits (typ. ± 12 ppm DC V) |
||||||||||
8.5 digits (typ. ± 3.9 ppm DC V) |
||||||||||
Temperature/pressure | ||||||||||
RTD simulate | ||||||||||
RTD measure | ||||||||||
Thermocouple simulate | ||||||||||
Thermocouple measure | ||||||||||
Pressure modules | ||||||||||
Oscilloscopes | 1 channel | 1 to 5 channels | ||||||||
200 MHz to 600 MHz | 200 MHz opt | 600 MHz opt | 600 MHz opt | 600 MHz opt | 600 MHz std | |||||
1.1 GHz | 1.1 GHz opt | 1.1 GHz opt | 9510 Head opt | |||||||
2.1 GHz | 2.1 GHz opt | |||||||||
3.2 GHz | 9530 Head opt | |||||||||
6.4 GHz | 9560 Head opt | |||||||||
25 ps fast edge (14 GHz) | 9550 Head opt | |||||||||
Safety testers | ||||||||||
Hipot | ||||||||||
Megohm meters | MEG opt | |||||||||
Installation | ||||||||||
PATs | ||||||||||
Continuity | MEG opt | |||||||||
Loop impedance | ||||||||||
Leakage current | ||||||||||
Ground bond | ||||||||||
RCD/GFCI | ||||||||||
Medical safety | ||||||||||
Power/energy | ||||||||||
Wattmeters | ||||||||||
Harmonic analyzers | ||||||||||
Flicker meters | ||||||||||
Phase angle meters | ||||||||||
Power analyzers | ||||||||||
Power recorders | ||||||||||
Secondary energy standards | ||||||||||
Watt-hour/energy meters | ||||||||||
Other | ||||||||||
Clamp meters | ||||||||||
LCR meters | RC only | LRC | LRC | |||||||
Process calibrators | ||||||||||
Data acquisition | ||||||||||
Non sine waveforms | ||||||||||
RF millivolt meters | 30 and 50 MHz WB opt | |||||||||
# of calibrator functions | 8 | 11 | 11 | 11 | 5 | 11+ | 9 | 8 | 8 | 9 |
For additional help selecting an electrical calibrator, speak with one of our equipment specialists.
Specifications subject to change without notice.
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- About Us