- Transfer standard level measurement uncertainty, ± 0.01 % of reading (± 0.008 % for dual channel mode)
- Single channel or dual channel with parallel measurementmode to reduce uncertainty and increase reliability
- Large, easy to read display
- RS232 and IEEE-488 interfaces included
- On-board functions including adjustable average time, high/low, deviation from set point, rate, freeze
- 17025 accredited calibration included in purchase price.
- Ideal for absolute pressure AutoZeroing of pressure transfer standards and molbox flow terminals
- Compact and rugged presentation
- Optional battery pack
The RPM4 BA100K is a full function laboratory quality barometer intended to measure atmospheric pressure with the very highest performance. Its outstanding pressure measurement specifications are made possible by DHI's exclusive quartz reference pressure transducer (Q-RPT) modules.
RPM4 BA100K (Single Channel) | RPM4 BA100K/BA100K (Dual Channel) | |
---|---|---|
Range | 70 kPa to 110 kPa (10 psia to 16 psia) | |
Power requirements | 85 V ac to 264 V ac, 50/60 Hz; 12 V dc, 1.2 A (battery) | |
Weight | 5 kg (11 lb) | |
Dimensions (H x W x D) | 10 cm x 22.7 cm x 24 cm (3.9 in. x 8.9 in. x 9.5 in.) | |
Test port connections | 1/8 in NPT F | |
Communications ports | RS232 (COM1, COM2), IEEE-488.2 Resolution To 1 ppm, user adjustable To 1 ppm, user | |
Resolution | To 1 ppm, user adjustable | |
Operating temperature | 15 °C to 35 °C (59 °F to 95 °F) | |
Warm up time | 30 minute temperature stabilization recommended from cold power up | |
Vibration | Meets MIL-T-28800D | |
Predicted Stability1 | ± 0.005 % of reading | ± 0.0032 % of reading |
Precision2 | ± 0.008 % of reading | ± 0.006 % of reading |
Measurement Uncertainty3 | ± 0.01 % of reading | ± 0.008 % of reading |
1Predicted Q-RPT measurement stability limit (k=2) over one year assuming regular use of AutoZero function. AutoZero is performed by the operator by comparison with a barometric reference in absol mode. Absolute mode predicted one year stability without AutoZ is: Single Channel ± (5 Pa + 0.005 % of reading), D Channel ± (4 Pa + 0.0032 % of reading). 2Combined linearity, hysteresis, repeatability. 3Maximum deviation of the Q-RPT indication from the true value of applied spressure including precision, predicted one year stability limit, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.” |
Model Name | Descripción |
---|---|
RPM4 mhhhac/mlllac |
Monitor de presión de referencia Donde: Consulte el Q-RPT y la tabla de intervalos situada debajo de "Características" para ver los Q-RPT disponibles. |
RPM4 04 |
-1 versión de unidades de Estados Unidos, -2 versión de unidades del sistema métrico |
RPM4 05 |
Marca de CE |
RPM4 06 |
Calibración especial |
RPM4 07 |
Fluido de prueba especial, Q-RPT alto (especificar fluido) |
RPM4 08 |
Fluido de prueba especial, Q-RPT bajo (especificar fluido) |
RPM4 09 |
-1 configuración especial, datos del aire (sólo A160K/A160K, A350K/A160K) |
RPM4-LP |
Monitor de baja presión, -15 a 15 kPa (-60 a 60 inH2O) |
Accessories common to all models:
Accesorio | Descripción |
---|---|
Batería/cargador |
Batería de 12 V CC con cargador |
Kit de montaje en bastidor |
Kit de montaje en bastidor para bastidor estándar de 19 pulgadas |
Pedal |
Pedal [ENTER] remoto (n.º de pieza 3070940) |
MPC1-3000 |
Controlador de presión de gas manual, vacío del intervalo de presión a 20 MPa (3.000 psi) |
MPC1-1000 |
Controlador de presión de gas manual, vacío del intervalo de presión a 7 MPa (1.000 psi) |
GPC1-16000 / GPC1-10000 |
Controlador de presión de gas |
MPG1-200M 402122 |
Controlador/generador de presión hidráulica manual, 200 MPa (30.000 psi) |
MPG2-H |
Controlador/generador de presión hidráulica manual, 200 MPa (30.000 psi) |
OPG1-30000 |
Generador de presión hidráulica. Incluye: 0,94 litros (1/4 galón) de di-2 etilhexil sebacato (aceite sintético), adaptadores o conexiones externas para la conexión a un PG7302 o RPM4, y manual de funcionamiento y mantenimiento. |
PK-7000-PPC/MPC |
Kit de interconexiones: conexión del PG7102 a un controlador de presión PPC o MPC y a un dispositivo en pruebas. |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- About Us
Sidebar Request a Quote
Solicitar una cotización