High performance function generator
- High stability 10 MHz DDS function generator
- Arbitrary capability with storage for five user defined waveforms
- Multiple standard and complex waveforms recalled from internal memory
- Extensive modulation capabilities include sweep, AM, Gating, Trigger/Burst, FSK and Hop
- GPIB and RS-232 interfaces
The 271 is a high performance function generator using Direct Digital Synthesis techniques. A wide variety of standard waveforms are provided and an arbitrary waveform capability allows it to be used to generate non-standard and user-defined waveforms. Extensive modulation capabilities make this a highly versatile signal source.
Waveforms
Standard waveforms are sine, square, positive pulse, negative pulse, triangle, ramp up, ramp down. Additionally arbitrary waveforms, multi-level squarewaves, waveform hopping and pseudo-random noise can be generated.
Direct digital synthesis for accuracy and stability
Direct digital synthesis (DDS) is a technique for generating waveforms digitally, using a phase accumulator, a look-up table and a DAC. The accuracy and stability of the resulting waveforms is related to that of the crystal master clock.
The DDS generator offers not only exceptional accuracy and stability but also high spectral purity, low phase noise and excellent frequency agility.
A wide range of waveforms
The Fluke 271 generates high quality sine, square and pulse waveforms over the full frequency range of 0.1 mHz to 10 MHz. Triangle waveforms, ramp waveforms and multi-level square waves can also be generated, subject to some limitations in the maximum useable frequencies. Variable symmetry/duty-cycle is available for all waveforms.
Arbitrary waveform capability
Arbitrary waveforms can be loaded via the digital interfaces and then used in a similar way to the standard waveforms.
Up to five arbitrary waveforms of 1024 10-bit words can be stored in non-volatile memory. The waveform clock is 27.48 MHz maximum. This facility considerably expands the versatility of the 271, making it suitable for the generation of highly complex waveform patterns.
In addition, the 271 offers numerous “complex” waveforms pre-defined in ROM. These include commonly used wave shapes such as sine x/x, decaying sinewave, and exponential rise and fall.
Locked generators
The signals from the Clock In/Out socket and the Sync Out socket can be used to phase lock two or more generators. This feature can be used to generate multi-phase waveforms or locked waveforms of different frequencies.
Powerful modulation modes
Sweep. All waveforms can be swept over their full frequency range at a rate variable between 10 milliseconds and 15 minutes. The sweep is fully phase continuous. Sweep can be linear or logarithmic, single or continuous. Single sweeps can be triggered from the front panel, the trigger input, or the digital interfaces.
Two sweep markers are provided, which are adjustable while sweep is running. The markers can provide a visual indication of frequency points on an oscilloscope or chart recorder.
AM. Amplitude modulation is available for all waveforms and is variable in 1 % steps, up to 100 %.
FSK. Frequency shift keying provides phase coherent switching between two selected frequencies at a rate defined by the switching signal source. The rate can be set from dc to 50 kHz internally, or dc to 1 MHz externally.
Trigger/Burst. All waveforms are available as a triggered burst, whereby each positive edge of the trigger signal will produce one burst of the carrier, starting and stopping at the phase angle specified by the start-stop phase setting. The number of cycles in the burst can be set between 0.5 and 1023.
Gated. The gated mode turns the output signal on when the gating signal is high and off when it is low. Both triggered and gated modes can be operated from the internal trigger generator (0.005 Hz to 50 kHz) or from an external source (dc to 1 MHz).
Waveform hop. The generator can be set up to ‘hop’ between a number of different waveform setups, either at a pre-determined rate or in response to a manual or bus trigger. Up to 16 different hop waveforms can be defined in terms of frequency, amplitude, function, offset and duration, which is variable in 1 ms steps up to 60 seconds.
Noise generation. The Fluke 271 can be set to simulate wide band random noise with adjustable amplitude and offset.
Waveforms | |||||||||||
Frequency |
|
||||||||||
Sinewave |
|
||||||||||
Squarewave |
|
||||||||||
Triangle |
|
||||||||||
Positive and Negative Ramp |
|
||||||||||
Positive and Negative Pulse |
|
||||||||||
Multi-Level Squarewave |
|
||||||||||
Arbitrary (and complex) |
|
||||||||||
Symmetry |
|
Main Output | |
Output impedance | 50 Ω or 600 Ω switchable |
Amplitude | 5 mV to 20 V pk-pk open circuit (2.5 mV to 10 V into 50 Ω/600 Ω). Output can be specified as V-H: 2
(open circuit value) or V (Voltage into the characteristic impedance) in pk-pk, RMS or dBm. Note that in positive or negative pulse modes the amplitude range is 2.5 mV to 10 V pk-pk O/C. |
Accuracy | Typically ±3 % ±1 mV at 1 kHz into 50 Ω/600 Ω |
Flatness | ±0.2 dB to 500 kHz; ±1 dB to 10 MHz |
Pulse aberrations | <5 %+ 2 mV |
DC offset | ± 10 V from 50Ω/600 Ω offset plus signal peak limited to ± 10 V from 50 Ω/600 Ω |
Resolution | 3 digits or 1 mV for both amplitude and offset |
Modulation | |||||||||||
Amplitude Modulation |
|
||||||||||
Frequency Shift Keying (FSK) |
|
Operating Modes | |||||||||||||
Trigger/burst |
|
||||||||||||
Gated |
|
||||||||||||
Sweep |
|
||||||||||||
Hop |
|
||||||||||||
Start/Stop Phase |
|
||||||||||||
Trigger Generator | Internal source 0.005 Hz to 50 kHz squarewave adjustable in 20 us steps. 3 digit resolution. Available for external use from TRIG/SWEEP OUT socket. |
Auxiliary Outputs | |
Aux Out | CMOS/TTL levels with symmetry and frequency of main output and phase of start-stop phase setting |
Trig/Sweep Out | Multi-function output depending upon mode. Except in sweep mode, the output is that of the trigger generator at CMOS/TTL levels from 1 kW.
In Sweep mode the output is a 3-level waveform, changing from high (+4 V) to low (0 V) at the start of sweep, with narrow 1 V pulses at each marker point. |
Inputs | |||||||
Ext Trig |
|
||||||
VCA In |
|
Phase Locking | |
Clock in/out | TTL/CMOS threshold levels; output impedance typically 50 Ω as an output |
Sync out | TTL/CMOS logic levels from typically 50 Ω. The signals from these sockets are used to phase lock two or more generators. |
Interfaces | |
RS-232 | Variable Baud rate, 9600 Baud maximum. 9-pin D-connector. |
IEEE-488 | Conforming with IEEE488.1 and IEEE488.2 |
General Specifications | |
Display | 20 character x 4 row alphanumeric LCD |
Data entry | Keyboard selection of mode, waveform etc.; value entry direct by numeric keys or by rotary control. |
Stored settings | Up to 9 complete instrument set-ups may be stored and recalled from battery-backed memory. |
Size | 3U (130 mm) height; half-rack (212 mm) width, 330 mm long |
Weight | 4.1 kg (9 lb) |
Power | 100 V ac, 110 to 120 V ac or 220 to 240 V ac +/– 10 %, 50/60 Hz ac by internal adjustment; 30 VA max. |
Operating range | +5 °C to 40 °C, 20 to 80 % RH |
Storage range | –20 °C to +60 °C |
Options | IEEE-488 interface; 19-in rack mounting kit |
Model Name | Description |
---|---|
271 |
10 MHz DDS Function Generator with Serial Cable |
Accessories common to all models:
Accessory | Description |
---|---|
Y200H |
Rack Mount Kit |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- About Us
Sidebar Request a Quote
Request a quote