A primary standard for ratio measurements
Model 720A Kelvin-Varley Divider is a high-resolution primary ratio standard with absolute linearity of 0.1 ppm, temperature coefficient of linearity of 0.1 ppm/ºC, and self-calibration capability.
- 0.1 ppm resolution, seven decades
- 0.1 ppm of input absolute linearity
- Built-in self calibration bridge
- Front panel self-calibration
A primary standard for ratio measurements
Model 720A Kelvin-Varley Divider is a high-resolution primary ratio standard with absolute linearity of 0.1 ppm, temperature coefficient of linearity of 0.1 ppm/ºC, and self-calibration capability.
- 0.1 ppm resolution, seven decades
- 0.1 ppm of input absolute linearity
- Built-in self calibration bridge
- Front panel self-calibration
General specifications |
|
Ratio range |
0 to 1.0 (1.0 input tap) and 0 to 1.1 (1.1 input tap) |
Resolution |
0.1 ppm of input with seven decades 0.2 |
Absolute linearity |
(At calibration temperature and without the use of a correct chart) ±1.0 ppm of input at dial settings of 1.1 to 0.1, ±0.1 (10S)1/3 of input at dial settings (S) of 0.1 to 0 |
Absolute linearity stability |
(Without self-calibration) ±1.0 ppm of input/yr at dial settings of 1.1 to 0.1, ±1.0 (10S)(2/3) ppm of input/yr at dial setting (S) of 0.1 to 0 Note: Absolute linearity is defined as the linearity between max and min output voltages. The self-calibration procedure may be used at any time to reset absolute linearity to ±0.1 ppm of input. |
Temperature coefficient of linearity |
±0.05 ppm of input ºC maximum at dial settings of 1.1 to 0.1 |
Short-term linearity stability |
Under typical standards laboratory conditions (temperature maintained within ± 1 ºC) and with an applied voltage of up to 100V, stability of linearity is ± 0.01 ppm/24 hours and ± 0.1 ppm/30 days |
Power coefficient of linearity |
±0.2 ppm of input/W max at dial settings of 1.1 to 0.1; ±0.2 (10S)2 ppm of input/W max at dial settings (S) of 0.1 to 0 |
Maximum end errors |
Zero error at output low: 0.004 ppm of input Zero error at input low: 0.05 ppm of input Full-scale error: 0.05 ppm of input |
Maximum input voltage |
1000 V on 1.0 input terminal, 1100 V on 1.1 input terminal |
Thermal voltages |
±0.5 μV max |
Input resistance |
100 kΩ ±0.005% at 1.0 input terminal at 25 °C, 110 kΩ ±0.005% at 1.1 input terminal at 25 °C |
Temperature coefficient of input resistance |
±1 ppm per °C max |
Size |
14 cm H x 48.2 cm W x 33 cm D, rack mounted (5.5 in H x 19 in W x 13 in D) |
Weight |
8.15 kg (18 lb) |
Model Name | Description |
---|---|
720A |
Kelvin-Varley Voltage Divider |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- About Us
Sidebar Request a Quote
Request a quote