World’s smallest, lightest and most portable dry-wells
- Smallest dry-wells in the world
- Ranges from –10°C to 375°C
- Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
- RS-232 interface
Fluke Calibration's line of portable dry-wells is incredible. They’re the smallest, lightest, and most portable dry-wells in the world. And now they're better than ever!
9100S Dry-Well
Since we introduced the world’s first truly handheld dry-well, many have tried to duplicate it—in vain. Despite its small size (2¼ inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world.
It’s simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375°C (707°F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.
Plug it in, switch it on (Note, these wells are fixed and not interchangeable,) set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Compare the reading of your device to the display temperature or to an external reference, and the difference is the error in your device. With a proprietary Fluke Calibration temperature controller, the 9100S has a display resolution of 0.1 degrees, an accuracy of ±0.5°C, a stability of ±0.1°C, and a stabilization time of just five minutes.
9102S Dry-Well
For work in the temperature range of –10°C to 122°C, our Model 9102S dry-well is another first in the industry, featuring stability to ±0.05°C.
This dry-well is only four inches high and six inches wide, achieves temperatures as low as –10°C, includes a NIST-traceable calibration, and is stable to ±0.05°C. The Model 9102S is excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient.
The 9102S has two wells so you can use one for a reference thermometer to increase accuracy. Both wells are 1/2 inch in diameter, and each has inserts available for almost any sensor size.
Specifications | 9100S | 9102S |
Range | 35 °C to 375 °C (95 °F to 707 °F | –10 °C to 122 °C (14 °F to 252 °F) at23 °C ambient |
Accuracy | ± 0.25 °C at 50 °C; ± 0.25 °C at 100 °C; ± 0.5 °C at 375 °C | ± 0.25 °C |
Stability | ± 0.07 °C at 50 °C; ± 0.1 °C at 100 °C; ± 0.3 °C at 375 °C | ± 0.05 °C |
Well-to-Well Uniformity | ± 0.2 °C with sensors of similar size at equal depths within wells | |
Heating Times | 35 °C to 375 °C: 9.5 minutes | ambient to 100 °C: 10 minutes |
Stabilization | 5 minutes | 7 minutes |
Cooling Times | 375 °C to 100 °C: 14 minutes | ambient to 0 °C: 10 minutes |
Well Depth | 102 mm (4 in);1.6 mm (1/16 in) hole is 89 mm (3.5 in) deep | 102 mm (4 in) |
Removable Inserts; | N/A | Available in sizes from 1.6 mm (1/16 in) to 11.1 mm (7/16 in) [6.4 mm (1/4 in) and 4.8 mm (3/16 in) included] |
Power | 115 V ac (± 10 %), 55–65 Hz, 1.5 A or 230 V ac (± 10 %), 0.8 A, 45–55 Hz, 175 W | 94-234 V ac (± 10 %), 50/60 Hz, 60 W |
Size (HxWxD) | 57 x 125 x 150 mm (2.25 x 4.9 x 6.1 in) | 99 x 140 x 175 mm (3.9 x 5.5 x 6.9 in) |
Weight | 1 kg (2 lb 3 oz) | 1.8 kg (4 lb) |
Computer Interface | RS-232 interface | |
NIST-TraceableCalibration | Data at 50 °C, 100 °C, 150 °C, 200 °C,250 °C, 300 °C, and 375 °C | Data at –10 °C, 0 °C, 25 °C, 50 °C, 75 °C,100 °C, and 122 °C |
Model Name | Description |
---|---|
9100S-A |
HDRC Handheld Dry-Well A |
9100S-B |
HDRC Handheld Dry-Well B |
9100S-C |
HDRC Handheld Dry-Well C |
9100S-D |
HDRC Handheld Dry-Well D |
9102S |
HDRC Handheld Dry-Well |
Accessories common to all models:
Accessory | Description |
---|---|
3102-0 |
Insert, AL 1/2" X 4" blank |
3102-1 |
Insert, AL 1/2" X 4" 1/16" |
3102-2 |
Insert, AL 1/2" X 4" 1/8" |
3102-3 |
Insert, AL 1/2" X 4" 3/16" |
3102-4 |
Insert, AL 1/2" X 4" 1/4" |
3102-5 |
Insert, AL 1/2" X 4" 5/16" |
3102-6 |
Insert, AL 1/2" X 4" 3/8" |
3102-7 |
Insert, AL 1/2" X 4" 7/16" |
3102-8 |
Insert, AL 1/2" X 4" 5/32" |
9300 |
Rugged Carrying Case: 9100S |
9308 |
Rugged Carrying Case for these models:
|
HART DRYWELL CABLE |
An interface cable kit that includes a null modem to connect the Fluke 754 with Fluke Calibration dry-wells and Micro-Baths to automate and document the calibration of temperature sensors and transmitters in the field or at the bench. |
Priority Gold Instrument CarePlan |
Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 800-882-6153 or send email to premiumcare@fluke.com. |
Silver CarePlan |
Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com. |
Product Manuals |
---|
Brochures |
---|
Application Notes |
---|
Papers / Articles |
---|
Improving Dry-Well Calibrations |
Selecting a Dry-Well (Dry-Block) Temperature Calibrator |
Video |
---|
How to Calibrate a Digital Thermometer with a Dry-Block Calibrator and with Freezing and Boiling Water |
Introduction to Dry Block Calibrators |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- About Us
Sidebar Request a Quote
Request a quote