- Other Fluke companies:
- Fluke
- Fluke Biomedical
- Fluke Networks
- Fluke Process Instruments
- Transfer standard level measurement uncertainty, ± 0.01 % of reading (± 0.008 % for dual channel mode)
- Single channel or dual channel with parallel measurementmode to reduce uncertainty and increase reliability
- Large, easy to read display
- RS232 and IEEE-488 interfaces included
- On-board functions including adjustable average time, high/low, deviation from set point, rate, freeze
- 17025 accredited calibration included in purchase price.
- Ideal for absolute pressure AutoZeroing of pressure transfer standards and molbox flow terminals
- Compact and rugged presentation
- Optional battery pack
The RPM4 BA100K is a full function laboratory quality barometer intended to measure atmospheric pressure with the very highest performance. Its outstanding pressure measurement specifications are made possible by DHI's exclusive quartz reference pressure transducer (Q-RPT) modules.
RPM4 BA100K (Single Channel) | RPM4 BA100K/BA100K (Dual Channel) | |
---|---|---|
Range | 70 kPa to 110 kPa (10 psia to 16 psia) | |
Power requirements | 85 V ac to 264 V ac, 50/60 Hz; 12 V dc, 1.2 A (battery) | |
Weight | 5 kg (11 lb) | |
Dimensions (H x W x D) | 10 cm x 22.7 cm x 24 cm (3.9 in. x 8.9 in. x 9.5 in.) | |
Test port connections | 1/8 in NPT F | |
Communications ports | RS232 (COM1, COM2), IEEE-488.2 Resolution To 1 ppm, user adjustable To 1 ppm, user | |
Resolution | To 1 ppm, user adjustable | |
Operating temperature | 15 °C to 35 °C (59 °F to 95 °F) | |
Warm up time | 30 minute temperature stabilization recommended from cold power up | |
Vibration | Meets MIL-T-28800D | |
Predicted Stability1 | ± 0.005 % of reading | ± 0.0032 % of reading |
Precision2 | ± 0.008 % of reading | ± 0.006 % of reading |
Measurement Uncertainty3 | ± 0.01 % of reading | ± 0.008 % of reading |
1Predicted Q-RPT measurement stability limit (k=2) over one year assuming regular use of AutoZero function. AutoZero is performed by the operator by comparison with a barometric reference in absol mode. Absolute mode predicted one year stability without AutoZ is: Single Channel ± (5 Pa + 0.005 % of reading), D Channel ± (4 Pa + 0.0032 % of reading). 2Combined linearity, hysteresis, repeatability. 3Maximum deviation of the Q-RPT indication from the true value of applied spressure including precision, predicted one year stability limit, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.” |
型式 | 詳細 |
---|---|
RPM4 mhhhac/mlllac |
基準圧力モニター ここで、 使用可能な Q-RPT については、「特徴」の Q-RPT およびレンジの表を参照してください。 |
RPM4 04 |
-1 米国単位版 -2 SI 単位版 |
RPM4 05 |
CE マーク |
RPM4 06 |
特別校正 |
RPM4 07 |
特殊試験液、Hi Q-RPT(液体を指定) |
RPM4 08 |
特殊試験液、低 Q-RPT(液体を指定) |
RPM4 09 |
-1 特殊構成、エアー・データ(A160K/A160K、A350K/A160Kのみ) |
Accessories common to all models:
アクセサリ | 詳細 |
---|---|
バッテリー・パック/充電器 |
12 V DCバッテリー、充電器付き |
ラック・マウント・キット |
ラック・マウント・キット、標準19 in ラック用 |
フット・スイッチ |
リモート[ENTER]フット・スイッチ(部品番号3070940) |
MPC1-3000 |
手動操作によるガス圧力コントローラー、真空から20 MPa(3,000 psi)までの圧力レンジ |
MPC1-1000 |
手動操作によるガス圧力コントローラー、真空から7 MPa(1,000 psi)までの圧力レンジ |
GPC1-16000 / GPC1-10000 |
ガス圧力コントローラー |
MPG1-200M 402122 |
手動油圧式ジェネレーター/コントローラー、200 MPa(30,000 psi) |
MPG2-H |
手動油圧式ジェネレーター/コントローラー、200 MPa(30,000 psi) |
OPG1-30000 |
油圧式ジェネレーター - 内容: 1 qt セバシン酸ビス(2-エチルヘキシル)(合成潤滑油)、PG7302またはRPM4用外部チューブ/アダプター、操作および保守マニュアル |
PK-7000-PPC/MPC |
相互接続キット - PG7102を PPCまたはMPC圧力コントローラー、および被試験装置に接続します。 |
- Home
- Products
- New Products
- Electrical Calibration
- RF Calibration
- Data Acquisition and Test Equipment
- Temperature Calibration
- Humidity Calibration
- Pressure Calibration
- Flow Calibration
- Process Calibration Tools
- Calibration Software
- Service and Support
- All Calibration Instruments
- Handheld Test Tools
- Purchase Info
- News
- Training and Events
- Literature and Education
- Service and Support
- About Us
Sidebar Request a Quote
見積依頼フォーム